Please use this identifier to cite or link to this item:
http://univ-bejaia.dz/dspace/123456789/26974Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Oubellout, Macelia | - |
| dc.contributor.author | Hamdi, Messaoud ; promoteur | - |
| dc.contributor.author | Benslimane, Abdelhakim ; co-promoteur | - |
| dc.date.accessioned | 2026-02-05T12:43:53Z | - |
| dc.date.available | 2026-02-05T12:43:53Z | - |
| dc.date.issued | 2025 | - |
| dc.identifier.uri | http://univ-bejaia.dz/dspace/123456789/26974 | - |
| dc.description | Spécialité : Installation énergétique et turbomachine. | en_US |
| dc.description.abstract | Mon travail a été réalisé à l’issue d’un stage pratique effectué au sein du complexe CEVITAL. Il a consisté en l'étude d'une installation de compresseur d'air comprimé CEVITAL-Bejaia -, incluant son dimensionnement énergétique, desservant les chaînes de production de l’entreprise. Mon but était de minimiser les pertes de charge opérant tout au long de la canalisation. Pour cela, j'ai procédé au calcul du débit volumique total de distribution et à l'évaluation de ces pertes. Je me suis également intéressé à l’analyse des performances du compresseur, notamment sa pression de refoulement, dans laquelle j'ai effectué une étude thermodynamique du compresseur à vis afin de déterminer sa consommation en énergie électrique. My work was carried out following a practical internship at the CEVITAL complex. It consisted of studying a CEVITAL-Bejaia compressed air compressor installation, including its energy dimensioning, serving the company's production lines. My goal was to minimize the pressure losses operating throughout the pipeline. To do this, I calculated the total distribution volumetric flow rate and evaluated these losses. I was also interested in analyzing the compressor's performance, particularly its discharge pressure, in which I conducted a thermodynamic study of the screw compressor to determine its electrical energy consumption. | en_US |
| dc.language.iso | fr | en_US |
| dc.publisher | Université A. Mira de Bejaia | en_US |
| dc.subject | Air comprimé : Pression de réservoir : Pression de refoulement : Pertes de charges : Puissance du compresseur | en_US |
| dc.title | Etude d'une installation de compresseur d'air comprimé, cevital-bejaia | en_US |
| dc.type | Thesis | en_US |
| Appears in Collections: | Mémoires de Master | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 621MAS 906 Etude d'une installation de compresseur d'air comprimé, CEVITAL-Bejaia-.pdf | 2.83 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.