| dc.description | Spécialité : Energétique | en_US |
| dc.description.abstract | Ce mémoire analyse les performances du réseau d’air comprimé de l’unité de conditionnement de sucre de Cevital, en comparant modélisation et mesures réelles. Les résultats montrent un sous-dimensionnement des canalisations et une architecture inadaptée, entraînant des pertes de charge élevées, une chute de pression instable et une surconsommation énergétique. Deux solutions ont été évaluées : le redimensionnement des tuyauteries et la reconfiguration en réseau bouclé. Cette dernière offre une meilleure régulation de la pression et une réduction de la consommation énergétique globale. En conclusion, cette analyse souligne l’importance d’une approche énergétique et pneumatique pour améliorer l’efficacité du système. Les recommandations formulées permettront à Cevital de moderniser son réseau d’air comprimé, contribuant ainsi à une amélioration notable de sa performance industrielle, économique et environnementale This thesis analyses the performance of the compressed air network in Cevital's sugar packaging unit, by comparing theoretical modelling (flow rates, pressure drops, pressure) with actual field measurements. The results reveal undersized piping and an inadequate layout, leading to high pressure losses, unstable pressure drop, and excessive energy consumption. Two solutions were evaluated: resizing the pipes and reconfiguring the network into a looped system. The latter provides better pressure regulation and a significant reduction in overall energy consumption. In conclusion, this analysis highlights the importance of an energy and pneumatic approach to improving system efficiency. The recommendations provided will enable Cevital to modernize its compressed air network, thereby contributing to a significant improvement in its industrial, economic, and environmental performance | en_US |
| dc.language.iso | fr | en_US |
| dc.publisher | Université A. Mira de Bejaia | en_US |
| dc.subject | Air comprimé, compresseur à vis, perte de charge : Optimisation énergétique :Réseau d’air comprimé : Cevital. | en_US |
| dc.title | Optimisation du circuit d’air comprimé dans l’unité de conditionnement de sucre CEVITAL-Bejaia | en_US |